7.3 Flue gas discharge and air supply
7.3.1 General
The Remeha Quinta 85 is suitable for conventional room ventilated or room sealed
operation. Specify at the time of ordering if the boiler is to be installed for twin pipe
room sealed operation. In that case, the boiler will be supplied with an optional adaptor
plate (concentric to twin pipe).
Before installing flue system, remove the transit cover plate/s.
Fig. 06 Top view Remeha Quinta (standard concentric version with optional twin
pipe adaptor shown right)
05.W4H.79.00006 + 00.W4H.79.00012
Horizontal components in the flue gas discharge system should slope towards the
boiler.
Horizontal components in the air supply system should slope towards the supply
opening.
Care should be taken when siting flue exit positions as a vapour plume will be visible
when the boiler is operational (flue gas temperature will be less than 75°C resulting in
the water vapour condensing out on contact with the air).