5.5 Setting the control strategy
The iSense lets you use the room control and/or weather-compensated control strategies
in various ways.
You can select a control strategy via Menu > Settings > System > Control settings
.
When implementing these changes, the user level must be set to “Extended mode”. (See
para. 5.1)
Specific settings for weather-compensated control
If you have opted for a weather-compensated control strategy, a number of extra settings are
available via Menu > Settings > System > OTC settings
.
Heating curve:
Base outside: outside temperature base point
Base flowtemp:ow temperature base point
Climate outside: outside temperature climate point
Climate flowtemp: flow temperature climate point
Curvature: degree of curvature of the heating curve, depending on your central heating system.
Select the relevant type of heaters: underfloor heating, radiators or convectors.
This will provide more comfort early and late in the year.
i
The heating curve is based on an outside temperature of 20°C. When the desired room
temperature is increased, the heating curve shifts upwards. The degree of increase is
determined using the “RT effect” function.
i