Page 1 - Timer thermostat

1i SenseTimer thermostatUser manual

Page 2

74. Priortorstuse4.1 Setting language, time and dateThemenuforselectingthelanguage(internationalversion)orsettingthetime(Dutchversio

Page 3 - Contents

8Clock programThe default clock program sets the temperature each day as follows:•06:00–19:00: 20°C(7days)•19:00– 23:00: 21°C(7days)•23:0

Page 4 - 2. Overview

95.2 Creating or changing a clock programA clock program automatically controls the temperature for a day, and can be set for each individualday.You

Page 5 - T000060-06-A

10An example of an overview is shown below: Time MO. TU. WE. TH. FR. SA. SU.7:009:0011:0013:0015:0017:0019:0021:0023:000:00T001003-06-Ai There

Page 6 - T000059-06-B

11Creating a new clock program1. Select Menu > Program > Clock program > New.2. Selectaninitialprogramifappropriate(Daytimehome,Mid

Page 7 - 3. Installation

12Changing an existing clock program1. Select Menu > Program > Clock program > Change.2. Go to the day for which you want to change the clo

Page 8 - T000062-C

135.3 Setting continuous temperaturesInstead of the clock program, you can also set the room temperature continuously to a particular value. You can s

Page 9

145.4 Setting the control strategyThe iSense lets you use the room control and/or weather-compensated control strategies in various ways.You can selec

Page 10 - 4. Priortorstuse

15higher than the night temperature that has been set via Menu > Program > Night temperature•Night temperature limit: outside temperature above

Page 11 - 5. Setting

16Heating curve – an example-5-15 5 15 25Outside temperature (ºC)Boiler temperature (ºC)10090807060504030201000Base pointT001032-06-AClimate pointDesi

Page 13 - T001003-06-A

175.5 Setting a holiday program It can be useful to set a holiday program if you are away from home for some time.This ensures a constant temperature

Page 14

185.6 Other settingsYou can change a number of settings via the Settings menu. These are summarised here; a more detailed explanation can be found in

Page 15

196. Using the iSense6.1 Selecting programYou can select one of the following programs via Program in the main display:• Clock program: the central

Page 16

203. PressAdjust date if you also want to set an end date for the manually selected temperature, and select this time using push-turn button C.4. P

Page 17

21i We advise that you close the radiator valves in the room in which the iSense has been positioned to prevent the room temperature there becoming t

Page 18

227.1 Fault messagesF200: No connection to outside sensorFault code F200 and are lit up.No connection to outside sensor.Check the b

Page 19 - T001032-06-A

23F214: Incorrect room temperature readingFault code F214 is lit up.Room temperature is out of measuring range or sensor is defective.Room temp

Page 20 - T001001-B

24F216: No connection with base station (iSense RF only)Fault code F216 and are lit up.Wireless communication fault.Check whether the i

Page 21

25Water pressure too lowCurrent water pressure and are lit up.The water pressure in your central heating system is too low.Top up t

Page 22 - 6. Using the iSense

26Controllerbatteriesat and are lit up.-The batteries are almost empty. Replace the three AA batteries. Fault indicationDisplay textSolu

Page 23

Contents1. Introduction ... 12. Overview ... 1 2.1 Display ...

Page 24 - 7. Messages

278. Problems and solutionsThe central heating is coming on too early in the morning.Adjust the Max. pre-heating time setting (see the installation a

Page 25 - 7.1 Fault messages

28The house is too warm.Weather-compensated control means that no account is taken of the measuredroom temperature. Solve the problem in one of the fo

Page 26 - F215: Controller failure

29It takes too long for the tap water to get up to temperature.- Boiler: the DHW standby function may be switched off. In that case the symbol

Page 27 - T001008a-06-A

30The boiler starts heating the home or the tap water at nighteven though the controller is set low.- Weather-compensated control (OTC) means that the

Page 28 - E-code:boilerfailure

31The temperature measurement differs from that which I am used to.Correct the temperature measurement via the Calibration setting (see the installati

Page 29 - Boiler service required

329.TechnicalspecicationsDimensions96x144x34(lxwxh)inmmHeightexcludingbuttons96x144x25(lxwxh)inmmPower supplyiSense OpenTh

Page 30 - 8. Problems and solutions

33Outside temperatureThe measurement is taken in the boiler and passed to the controller. Consult the boiler documentation regarding the accuracy of

Page 31 - T001022-06-A

34Setting accuracy Temperature:0.5°C.Clock program: 10 minutesWirelessrange(iSenseRF)Approximately8metresthrough2concretelayers(dependingo

Page 32 - T001254-06-A

35Appendix: clock program template Time MO. TU. WE. TH. FR. SA. SU.00.__01.__02.__03.__04.__05.__06.__07.__08.__09.__10.__11.__T001004-06-A T

Page 33 - T001024-06-A

118037 - 260608118037

Page 34 - T001027-06-A

11. IntroductionThe Remeha iSense is an OpenTherm timer thermostat with many enhanced functions.The iSense is supplied in two versions:• iSenseOpen

Page 35 - 9.Technicalspecications

22.1 DisplayTextboxmenusT000060-06-AMode button BMode button ATemperatureTimePictogramsMenuProgramMost important pictogramsT001001-AClock program acti

Page 36

32.2 ButtonsThe function of button A and button B depends on the task you are carrying out. The function is shown in the display, immediately above th

Page 37

43. Installation3.1 Location of the thermostatThe iSense is set to room control by default, which means that the inside temperature is used to contro

Page 38 - T001004-06-A

53.2 Installation and connectionThe following must be done before you install and connect the iSense:• Adjusttheboilersothatitcanbeconnected

Page 39 - 118037 - 260608

64. PlacethreeAAbatteriesinthethermostatifrequired. These are not provided. The batteries ensure that the clock keeps running when the boil

Comments to this Manuals

No comments